Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 8.237
Filtrar
1.
Am J Dent ; 37(1): 53-56, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38458984

RESUMO

PURPOSE: To evaluate flow profile and non-Newtonian behavior of 10 different silicone lining materials. METHODS: Ten commercially available silicone lining materials were selected for evaluation. The flow profile and non-Newtonian behavior of each material was measured using a shark fin testing method. Fin height and resultant base thickness were measured with a digital caliper and compared with one-way ANOVA and Student-Newman-Keuls post hoc test and fin base by Kruskal-Wallis one-way ANOVA on ranks with Dunn post hoc test with significance at P< 0.05 for both. RESULTS: Shark fin heights ranged from 9.62 ± 0.86 mm [Reline II (Soft)] to 25.54 ± 0.43 mm [Sofreliner (Medium)]. Shark fin bases ranged from 2.57 ± 0.51 mm [Sofreliner (Medium)] to 10.31 ± 0.57 mm [Reline II (Soft)]. Statistically significant differences were found between certain samples' shark fin heights as well as resultant bases (P< 0.05) indicating different rheological properties. CLINICAL SIGNIFICANCE: Silicone liner materials differ significantly with respect to flow profile and non-Newtonian behavior. While a high flow profile (low viscosity) of an elastomeric impression material improves accuracy, it may be a detriment to a denture lining material that must achieve a critical minimum thickness to provide resilience. Likewise, a low flow profile (high viscosity) material may also pose a disadvantage, requiring excessive compression and possible tissue distortion to achieve the same critical thickness. The results of this study should be considered when selecting the appropriate material for clinical application. Additional studies are indicated to further quantify rheological properties as well as correlate them to physical properties after the complete cure of the material.


Assuntos
Reembasadores de Dentadura , Silicones , Humanos , Viscosidade , Teste de Materiais , Bases de Dentadura , Elastômeros de Silicone , Propriedades de Superfície
2.
J Oral Sci ; 66(2): 116-119, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38447982

RESUMO

PURPOSE: This study investigated the color stability of different commercially available silicone materials for facial prostheses upon exposure to everyday beverages. It was hypothesized that the beverages would not alter the color of the silicone under conditions simulating daily exposure. METHODS: Sixty specimens were fabricated using two materials - VST-50 and Silfy - and exposed to commercially available cold mineral water, tea, or coffee. Specimen color was evaluated on days 1 and 15. The color was measured with a spectrophotometer based on CIELab system and color differences were calculated as ΔE. Statistical analysis was performed using the Kruskal-Wallis test and Mann-Whitney U test. RESULTS: The mean ΔE values after 15 days of exposure to mineral water, cold green tea, and coffee were 1.016, 3.480, and 3.636 for VST-50 and 0.440, 0.798, and 1.425 for Silfy, respectively. Both materials showed significant differences in color, and VST-50 showed a greater color change than Silfy, especially for coffee. CONCLUSION: Pigmented silicone elastomers have low color stability, leading to an overall color change in silicone prostheses when exposed to pigmented beverages. Color changes in such prostheses can be mitigated by selecting materials with better color stability to extend their longevity.


Assuntos
Prótese Maxilofacial , Águas Minerais , Elastômeros de Silicone , Cor , Café , Pigmentação em Prótese , Teste de Materiais , Bebidas
3.
J Long Term Eff Med Implants ; 34(3): 43-53, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38505893

RESUMO

The aim of this systematic review was to identify and analyze the findings of various studies that analyzed the changes in the color stability of maxillofacial prosthetic materials after the addition of various colorants and nanoparticles and assess the change in color after being subjected to either natural or artificial accelerated aging as well as outdoor aging. This systematic review was conducted in accordance with the guidelines of transparent reporting of systematic reviews and meta-analysis (PRISMA Statement). The primary objective of this systematic review was to evaluate the color stability of maxillofacial prosthesis. The secondary objective was to assess the effect of various colorants; pigments; opacifiers; UV absorbers-such as inorganic colorants (dry earth pigments); metal oxides; and organic colorants. The time period of the included studies extended from 2013 to 2023. Electronic database search identified a total of 217 studies. Ten studies were included to meet the research question. All 10 included studies analyzed the effect of various colorants and their exposure to various aging and weathering conditions. It was found that various pigments and nanoparticles had an effect on the color stability. Also weathering and aging conditions had a direct effect on the color stability as well. In terms of disinfection, although there was not much color difference observed, highest change in color stability was observed when rubbing or brushing of the prosthesis was carried out. In conclusion, the color stability of maxillofacial prosthetics is a critical factor that influences both patient satisfaction and the overall cosmetic look. The potential of pigments and nanoparticles to enhance the color stability of silicone-based maxillofacial prosthesis has received much research. By avoiding color fading and discoloration brought on by environmental variables including UV radiation, aging, and chemical exposure, the inclusion of various pigments and nanoparticles has been demonstrated to improve the color stability of silicone maxillofacial prostheses.


Assuntos
Prótese Maxilofacial , Pigmentação em Prótese , Humanos , Elastômeros de Silicone , Cor , Próteses e Implantes , Teste de Materiais
4.
J Microorg Control ; 29(1): 39-44, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38508761

RESUMO

During the disinfection of indoor spaces using gaseous hypochlorous acid (HOCl(g)), inhalation is the most common route of exposure for humans. In this study, an artificial human respiratory tract model was exposed to 12-140 ppb HOCl(g) at an aspiration flow rate of 800 mL/s for 15 h in a 1 m3 chamber. The respiratory tract model was equipped with 5th order bronchi and all gas-contact parts were made of silicone rubber with no other chlorine-consuming substances. The concentration of HOCl(g) reaching the lung pseudo-space was approximately 47.4% of the HOCl(g) concentrations in the chamber and was calculated to be very close to zero when the chamber concentration was less than 20.5 ppb. The disappearance of HOCl(g) during inhalation is likely due to the adsorption of HOCl(g) on the gas-contact silicone rubber surfaces. The cytotoxicity of HOCl(g) on respiratory epithelial cells was also examined using human air-liquid-interface airway tissue models. Human nasal epithelium and bronchiolar epithelium were exposed to 100 ppb and 500 ppb HOCl(g) for 8 h and 5 d, respectively. No significant effects of HOCl(g) on cell viability and ciliary activity were observed in any cell type, indicating that low concentrations of HOCl(g), less than 500 ppb, had no cytotoxic effect.


Assuntos
Gases , Ácido Hipocloroso , Humanos , Ácido Hipocloroso/farmacologia , Elastômeros de Silicone , Células Epiteliais , Pulmão
5.
Technol Cancer Res Treat ; 23: 15330338241229367, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38297814

RESUMO

Objective: To investigate the dosimetric effects of using individualized silicone rubber (SR) bolus on the target area and organs at risk (OARs) during postmastectomy radiotherapy (PMRT), as well as evaluate skin acute radiation dermatitis (ARD). Methods: A retrospective study was performed on 30 patients with breast cancer. Each patient was prepared with an individualized SR bolus of 3 mm thickness. Fan-beam computed tomography (FBCT) was performed at the first and second fractions, and then once a week for a total of 5 times. Dosimetric metrics such as homogeneity index (HI), conformity index (CI), skin dose (SD), and OARs including the heart, lungs, and spinal cord were compared between the original plan and the FBCTs. The acute side effects were recorded. Results: In targets' dosimetric metrics, there were no significant differences in Dmean and V105% between planning computed tomography (CT) and actual treatments (P > .05), while the differences in D95%, V95%, HI, and CI were statistically significant (P < .05). In OARs, there were no significant differences between the Dmean, V5, and V20 of the affected lung, V5 of the heart and Dmax of the spinal cord (P > .05) except the V30 of affected lung, which was slightly lower than the planning CT (P < .05). In SD, both Dmax and Dmean in actual treatments were increased than plan A, and the difference was statistically significant (P < .05), while the skin-V20 and skin-V30 has no difference. Among the 30 patients, only one patient had no skin ARD, and 5 patients developed ARD of grade 2, while the remaining 24 patients were grade 1. Conclusion: The OR bolus showed good anastomoses and high interfraction reproducibility with the chest wall, and did not cause deformation during irradiation. It ensured accurate dose delivery of the target and OARs during the treatment, which may increase SD by over 101%. In this study, no cases of grade 3 skin ARD were observed. However, the potential of using OR bolus to reduce grade 1 and 2 skin ARD warrants further investigation with a larger sample size.


Assuntos
Neoplasias da Mama , Dermatite , Radioterapia de Intensidade Modulada , Humanos , Feminino , Neoplasias da Mama/radioterapia , Neoplasias da Mama/cirurgia , Elastômeros de Silicone , Planejamento da Radioterapia Assistida por Computador/métodos , Dosagem Radioterapêutica , Estudos Retrospectivos , Reprodutibilidade dos Testes , Mastectomia/efeitos adversos , Radioterapia de Intensidade Modulada/efeitos adversos , Radioterapia de Intensidade Modulada/métodos , Tomografia Computadorizada por Raios X , Dermatite/cirurgia , Órgãos em Risco/efeitos da radiação
6.
Artigo em Inglês | MEDLINE | ID: mdl-38306955

RESUMO

1,3-dichlorobenzene (1,3-DCB) is an aromatic solvent that might be formed during thermal decomposition of bis(2,4-dichlorobenzoyl)peroxide used as initiator in silicone rubber production with many workers exposed worldwide. During metabolism of 1,3-DCB, two isomeric mercapturic acids can be formed from ring oxidation of 1,3-DCB in the liver, namely 2,4-dichlorophenylmercapturic acid (24CPhMA) and 3,5-dichlorophenylmercapturic acid (35CPhMA). These urinary mercapturic acids might serve as biomarkers of the toxicologically relevant absorbed dose of 1,3-DCB and have not been determined so far. Thus, we were aimed to develop an analytical method for quantification of these biomarkers. Authentic standards of both mercapturic acids as well as deuterium-labelled analogues were self-synthesized. A method for the quantification of both CPhMAs in human urine using online-SPE LC/MS/MS was developed and validated with an LOQ of 0.1 ng mL-1 for both CPhMAs. The analytes were extracted from urine by online-SPE on a restricted access material phase, transferred to the analytical column and quantified by tandem mass spectrometry. Interday (n = 6) and Intraday (n = 10) precision for both CPhMAs ranged from 1.7 to 4.3 % with accuracies between 99.4 and 109.9 % at concentrations of 0.6 and 3 ng mL-1. We applied the method on post-shift urine samples of 16 workers of the silicone rubber industry with occupational exposure to 1,3-DCB. Both CPhMAs were above LOQ in 15 of 16 urine samples with median levels (range) for 24CPhMA and 35CPhMA of 1.64 ng mL-1 (<0.1 - 8.2 ng mL-1) and 3.98 ng mL-1 (0.36 - 24.1 ng mL-1), respectively. This is the first report on specific urinary mercapturic acids of 1,3-DCB in humans. Our results show that ring oxidation of 1,3-DCB is considered to be a toxicologically relevant metabolic pathway in humans. This might improve risk assessment of 1,3-DCB-emissions in silicone rubber industry.


Assuntos
Clorobenzenos , 60705 , Espectrometria de Massas em Tandem , Humanos , Espectrometria de Massas em Tandem/métodos , Cromatografia Líquida/métodos , Acetilcisteína/química , Elastômeros de Silicone , Biomarcadores/urina , Isótopos
7.
J Biomed Mater Res B Appl Biomater ; 112(2): e35377, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38359174

RESUMO

Silicone rubber (SR), a common medical-grade polymer used in medical devices, has previously been modified for nitric oxide (NO) releasing capabilities. However, the effects of material properties such as film thickness on NO release kinetics are not well explored. In this study, SR is used in the first analysis of how a polymer's thickness affects the storage and uptake of an NO donor and subsequent release properties. Observed NO release trends show that a polymer's thickness results in tunable NO release. These results indicate how crucial a polymer's thickness is to optimize the NO release in an efficient and effective method.


Assuntos
Óxido Nítrico , Elastômeros de Silicone , Doadores de Óxido Nítrico
8.
Photodiagnosis Photodyn Ther ; 45: 103976, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38224726

RESUMO

BACKGROUND: Urethral injury occurs in 1-6 % of male cases during minimally invasive surgery of lower rectal cancer. A Foley catheter emitting near-infrared (NIR) fluorescence of sufficient intensity has been expected to locate the urethra during image-guided surgery. Although it has been difficult to impart NIR fluorescent properties to biocompatible thermosetting polymers, we have recently succeeded in developing a NIR fluorescent compound for silicone rubber and a NIR fluorescent Foley catheter (HICARL). Here, we evaluated its NIR fluorescence properties and visibility performance using porcine anorectal isolation specimens. METHODS: The HICARL catheter was made of a mixture of solid silicone rubber and a NIR fluorescent compound that emits fluorescence with a wavelength of 820-880 nm, while a conventional transparent Foley catheter was made of solid silicone rubber only. As a standard for comparison of the intensity of NIR fluorescence, a transparent Foley catheter the lumen of which was filled with a mixture of indocyanine green (ICG) and human plasma was used. As a comparison to assess the visibility performance of the HICARL catheter, a transparent Foley catheter into which a commercially available NIR fluorescent polyurethane ureteral catheter (NIRC) was placed was used. RESULTS: A NIR fluorescence quantitative imaging analysis revealed that the Foley-NIRC catheter and the HICARL catheter emitted 3.42 ± 0.42 and 6.43 ± 0.07 times more fluorescence than the Foley-ICG catheter, respectively. The location of the HICARL catheter placed in the anorectum with a wall thickness of 3.8 ± 0.1 mm was clearly delineated in its entirety by NIR fluorescence, while that of the Foley-NIRC catheter was faintly or only partially visible. CONCLUSIONS: The HICARL catheter emitting NIR fluorescence of sufficient intensity is a promising and easy-to-use tool for urethral visualization during image-guided surgery of lower rectal cancer.


Assuntos
Fotoquimioterapia , Neoplasias Retais , Cirurgia Assistida por Computador , Humanos , Masculino , Animais , Suínos , Elastômeros de Silicone , Fotoquimioterapia/métodos , Fármacos Fotossensibilizantes , Corantes , Verde de Indocianina/farmacologia , Cateteres , Neoplasias Retais/diagnóstico por imagem , Neoplasias Retais/cirurgia
9.
J Prosthet Dent ; 131(2): 340.e1-340.e6, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38212157

RESUMO

STATEMENT OF PROBLEM: Part 1 of this 2-part study determined that microwave disinfection did not degrade the color stability of facial silicone prostheses. However, investigations on the effects of microwave disinfection on the mechanical properties of different silicone elastomers are lacking. PURPOSE: The purpose of this in vitro study was to examine the mechanical properties of commonly used colored facial silicone elastomers before and after microwave disinfection over a simulated 1.5-year period. MATERIAL AND METHODS: Six commonly used facial silicone elastomers: MDX4-4210, MDX4-4210/Type A, M511, A-2186, VST-50, and A-2000 were combined with functional intrinsic silicone pigments and opacifier (red, yellow, blue, and white). A total of 288 specimens were fabricated (n=12). Half of the specimens were tested for mechanical properties as the baseline, while the other specimens were tested after microwave disinfection. Microwave disinfection was performed with 660 W, 6 minutes of exposure time, and microwaved for 18 cycles to simulate 1.5 years of usage (one 6-minute exposure monthly). For mechanical property testing, all specimens were tested for tensile strength and percentage elongation (ASTM D412), tear strength (ASTM D624), and hardness (ASTM D2240). For each property, a 2-way ANOVA (silicone type and microwave disinfection factors) and Tukey multiple comparison test were performed using the R statistical software program (α=.05). RESULTS: Following microwave disinfection, tensile strength and percentage elongation of A-2000 increased significantly (P<.05). MDX4-4210, MDX4-4210/Type A, and A-2000 showed significant increases in their hardness (P<.001). Tear strength also increased significantly for MDX4-4210 and VST-50 (P<.05). Among the materials tested (ranked from highest to lowest value,=not statistically significant different), for tensile strength, VST-50>A-2186=A-2000>MDX4-4210/Type A=M511=MDX4-4210 (P<.05). For percentage elongation, VST-50>MDX4-4210/Type A>A-2186>M511=A-2000=MDX4-4210=M511 (P<.05). For hardness, A-2000=A-2186>M511=VST-50>MDX4-4210>MDX4-4210/Type A (P<.05). For tear strength, VST-50>A-2186>A-2000>M511>MDX4-4210/Type A=MDX4-4210 (P<.05). CONCLUSIONS: Overall, the mechanical properties of all the silicones tested were not adversely affected by microwave disinfection. VST-50 showed the best mechanical properties among the materials tested both before and after microwave disinfection. Microwave energy is a safe method of disinfecting the silicone elastomers tested in this study.


Assuntos
Implantes Dentários , Dimetilpolisiloxanos , Prótese Maxilofacial , Elastômeros de Silicone , Desinfecção , Teste de Materiais , Micro-Ondas/uso terapêutico , Resistência à Tração
10.
Int J Prosthodont ; 37(1): 41-48, 2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-37222545

RESUMO

PURPOSE: To evaluate the effect of adding tea tree oil to denture liners on Candida albicans and bond strength to the acrylic denture base. MATERIALS AND METHODS: Disc-shaped specimens were fabricated from silicone-based resilient liner (Tokuyama, Molloplast), acrylic-based hard liner (GC Reline), and acrylic-based soft liner (Visco-gel). Tea tree oil (TTO) was incorporated into the liners at varying concentrations (0% [control], 2%, 5%, 8%). C albicans were counted by viable colony count, and optical density (OD) was measured with a spectrophotometer. The tensile strength to heat polymerized acrylic denture base was measured in a universal testing machine. The compliance of the data to the distribution of normality was evaluated using the Shapiro Wilk test. Two-way ANOVA, Bonferroni correction, and paired sample t test were performed (α = .05). RESULTS: The addition of TTO into liners provided a significant decrease in the OD values (P < .001). The control groups of the liners presented the highest colony counts, whereas increasing TTO decreased the results (P < .01). According to tensile bond strength test, 8% TTO addition resulted in a significant decrease for Tokuyama (P < .01) and Molloplast liners (P < .05), while 2% TTO resulted in significance for GC Reline (P < .001). CONCLUSIONS: Denture liners containing increasing percentages of TTO presented lower amounts of C albicans colonies and decreased bond strength to the denture bases. When using TTO for its antifungal properties, the amount added should be carefully selected because the tensile bond strength may be affected.


Assuntos
Colagem Dentária , Reembasadores de Dentadura , Óleo de Melaleuca , Elastômeros de Silicone/química , Bases de Dentadura , Candida albicans , Óleo de Melaleuca/farmacologia , Resinas Acrílicas/química , Teste de Materiais , Polimetil Metacrilato , Resistência à Tração
11.
Clin Pharmacol Ther ; 115(5): 1085-1091, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38159264

RESUMO

Episil is a bioadhesive barrier-forming liquid gel that can relieve mucositis caused by radiotherapy (RT) and effectively relieve pain. The purpose of this trial is to compare the efficacy and safety of Episil in improving acute radiation dermatitis (ARD) in patients with breast cancer. This study included patients who met the criteria for postoperative RT for breast cancer. The primary end point was the grade of RD during treatment. A total of 102 patients were included in this study. The patients were grouped in a 2:1 ratio using the randomized number table method: 67 patients received Episil combined with conventional skin care (the Episil group), whereas the remaining 35 patients served as the control group and received conventional skin care only (the control group). According to the grading criteria of the Radiation Therapy Oncology Group (RTOG), the skin reaction rate and severity were significantly better in the Episil group than the control group (24.62%, 72.31%, 3.08, 0, 0 vs. 0, 85.71%, 14.29%, 0, 0, 0) across grades 0 to 4 (P < 0.05). The itchiness score exhibited s significant reduction in the Episil group as compared with the control group (P < 0.05). The results of the European Organization for Research and Treatment of Cancer Quality of Life Questionnaire (EORTC QLQ-C30) showed that the overall health (z = -5.855, P < 0.001) and overall quality of life (z = -6.583, P < 0.001) were better in the Episil group than the control group after RT. Overall, in patients with breast cancer receiving RT, the topical application of Episil may significantly reduce the grading of ARD, alleviate patient symptoms, and improve the patient's overall quality of life.


Assuntos
Neoplasias da Mama , Radiodermatite , Elastômeros de Silicone , Humanos , Feminino , Neoplasias da Mama/radioterapia , Neoplasias da Mama/cirurgia , Qualidade de Vida , Radiodermatite/tratamento farmacológico , Dor
12.
Int J Biol Macromol ; 258(Pt 2): 129110, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38161016

RESUMO

Polymer modification using silicone rubber represents a promising avenue for enhancing physico-mechanical properties. However, achieving optimal performance through direct blending is hindered by the poor interface compatibility between silicone rubber and the matrix. In this study, we prepared super-tough thermoplastic vulcanizates (TPVs) of polylactic acid/silicone rubber through dynamic vulcanization with PLA, methyl vinyl silicone rubber (MVQ), glycidyl methacrylate grafted MVQ (MVQ-g-GMA), and fumed silica nanoparticles (SiO2). The impact of the SiO2 addition in MVQ on the morphology, mechanical properties, crystallization, and thermal properties of the TPVs was investigated. The results showed that MVQ-g-GMA and SiO2 exhibited a synergistic compatibilization effect significantly improving the interfacial adhesion between PLA and MVQ. Therefore, the impact and tensile strength of the TPVs increased from 8.0 kJ/m2 and 22.2 MPa to 62.6 kJ/m2 and 36.7 MPa, respectively. Moreover, the TPVs also presented good low-temperature toughness with a maximum impact strength of 40.4 kJ/m2 at -20 °C. Additionally, improvements in thermal stability and crystallization rate were also observed. Overall, combining organic and inorganic synergistic compatibilization is a feasible and effective method to fabricate outstanding low-temperature toughness to PLA.


Assuntos
Dióxido de Silício , Elastômeros de Silicone , Poliésteres , Polímeros
13.
Int J Mol Sci ; 24(23)2023 Nov 22.
Artigo em Inglês | MEDLINE | ID: mdl-38068948

RESUMO

The aim of this research was to obtain new polymer composites with a silicone rubber matrix, having favorable mechanical and functional properties. They contained admixtures in the amount of 10% by weight of expanded graphite (EG) or birch bark (BB). Additionally, some composites contained magnetic particles in the form of carbonyl iron in the amount of 20% by weight. The tensile strength, water absorption, frost resistance, surface contact angle, and free surface energy were examined. Microscopic images were taken using the SEM method and the content of some elements in selected microareas was determined using the EDXS method. In the study, a constant magnetic field with magnetic induction B was used, by means of which the properties and structure of polymer composites were modified. Scientific research in the field of polymers is the driving force behind the progress of civilization. Smart materials are able to respond to external stimuli, such as magnetic fields, with significant changes in their properties. The magnetic field affects not only chemical reactions, but also the crystallographic structure and physicochemical properties of the final products. Owing to their unique properties, such materials can be used in the space industry, automotive industry, or electrical engineering.


Assuntos
Polímeros , Elastômeros de Silicone , Polímeros/química , Elastômeros de Silicone/química , Fenômenos Químicos , Água , Campos Magnéticos
14.
Clin Oral Investig ; 27(12): 7799-7807, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37919552

RESUMO

OBJECTIVE: The aim of this in vitro study was to evaluate the effect of an oxide nanocoating to prevent colour degradation of maxillofacial silicone elastomers following accelerated ageing. MATERIAL AND METHODS: Specimens (N = 40) of specified dimensions were fabricated in Factor II room temperature vulcanizing (RTV) silicone and processed according to the manufacturer's instructions. Two groups were classified with 20 specimens each. Specimens in the first group were coated with titanium dioxide (TiO2) by atomic layer deposition technology. The colour stability test was conducted with a UV-VIS spectrometer (Schimadzu) for both titanium dioxide nanocoated and uncoated specimen groups after subjecting them to accelerated ageing. It was analysed using the CIE L*a*b method. RESULTS: The average colour change was highest for uncoated specimens (2.868), and the average colour change for titanium dioxide-coated specimens was significantly low (1.774). The average colour change of uncoated specimens (2.868) was close to the acceptable threshold value (3), and that of coated specimens (1.774) was far below the acceptable threshold (3). CONCLUSIONS: The colour change that occurred in titanium dioxide nanocoated specimens following accelerated ageing was significantly lower than that in the uncoated group, showing that the TiO2 nanocoating was effective in reducing the colour degradation of silicone elastomers. CLINICAL RELEVANCE: Maxillofacial prostheses fabricated from silicone elastomers go through undesirable colour degradation over time. The development of a scientific technique that retards the colour deterioration of silicone prostheses would be of great clinical significance.


Assuntos
Elastômeros de Silicone , Cor , Temperatura , Teste de Materiais
15.
Medicina (Kaunas) ; 59(11)2023 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-38003985

RESUMO

Background and Objectives: One's quality of life depends on overall health, and in particular, oral health, which has been and continues to become a public health issue through frequent manifestations in various forms, from simple oral stomatitis (inflammations of the oral cavity) to the complicated oral health pathologies requiring medical interventions and treatments (caries, pulp necrosis and periodontitis). The aim of this study focused on the preparation and evaluation of vitamins (vitamin A, B1 and B6) incorporated into several silicone-based lining materials as a new alternative to therapeutically loaded materials designed as oral cavity lining materials in prosthodontics. Materials and Methods: Silicone-based liners containing vitamins were prepared by mixing them in solution and becoming crosslinked, and then they were characterized using Fourier-transform infrared (FT-IR) spectroscopy to confirm the incorporation of the vitamins into the silicone network; scanning electron microscopy (SEM) to evidence the morphology of the liner materials; dynamic vapor sorption (DVS) to evaluate their internal hydrophobicity, swelling in environments similar to biological fluids and mechanical test to demonstrate tensile strength; MTT to confirm their biocompatibility on normal cell cultures (fibroblast) and mucoadhesivity; and histopathological tests on porcine oral mucosa to highlight their potential utility as soft lining materials with improved efficiency. Results: FT-IR analysis confirmed the structural peculiarities of the prepared lining materials and the successful incorporation of vitamins into the silicone matrix. The surface roughness of the materials was lower than 0.2 µm, while in cross-section, the lining materials showed a compact morphology. It was found that the presence of vitamins induced a decrease in the main mechanical parameters (strength and elongation at break, Young's modulus) and hydrophobicity, which varied from one vitamin to another. A swelling degree higher than 8% was found in PBS 6.8 (artificial saliva) and water. Hydrolytic stability studies in an artificial saliva medium showed the release of low concentrations of silicone and vitamin fragments in the first 24 h, which increased the swelling behavior of the materials, diffusion and solubility of the vitamins. The microscopic images of fibroblast cells incubated with vitamin liners revealed very good biocompatibility. Also, the silicone liners incorporating the vitamins showed good mucoadhesive properties. The appearance of some pathological disorders with autolysis processes was more pronounced in the case of vitamin A liners. Conclusions: The addition of the vitamins was shown to have a beneficial effect that was mainly manifested as increased biocompatibility, hydrolytic stability and mucoadhesiveness with the mucosa of the oral cavity and less of an effect on the mechanical strength. The obtained lining materials showed good resistance in simulated biological media but caused a pronounced autolysis phenomenon, as revealed by histopathological examination, showing that these materials may have broad implications in the treatment of oral diseases.


Assuntos
Reembasadores de Dentadura , Elastômeros de Silicone , Animais , Suínos , Elastômeros de Silicone/química , Vitaminas , Vitamina A , Mucosa Bucal , Qualidade de Vida , Saliva Artificial , Espectroscopia de Infravermelho com Transformada de Fourier , Teste de Materiais , Vitamina K
16.
J Indian Prosthodont Soc ; 23(4): 363-372, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37861613

RESUMO

Aim: The relatively short lifespan of maxillofacial prostheses (ranging from 3-24 months) is mostly a result of colour instability of silicone elastomers caused by ultraviolet (UV) radiation, requiring frequent remakes. An improvement in colour preservation could result in fewer remakes, thus saving time and money for both clinician and patient. In the quest for a suitable colour protection method, sunscreen protection products were considered; the most recent study on this subject was carried out in 1994, albeit using a low protection factor. The aim of this research was to determine if there is value in using topical sun protection products on extraoral silicone prostheses to prevent colour degradation. Settings and Design: This was an in vitro quantitative study. Materials and Methods: Three commercially available sunscreen products were studied, Riemann P20, Boots Soltan, and Garnier Ambre Solaire all with a sun protection factor of 50. A total of 144 silicone elastomer samples were produced using a Caucasian (light) shade 1.2 (n = 72) and dark skin shade 3.2 (n = 72) from the Technovent Ltd. Reality Shade range. Each shade group (n = 72) was divided into three groups to be subjected to outdoor weathering (n = 24), indoor (n = 24), and dark storage (n = 24). Within each environmental group, samples were divided into groups of six samples (n = 6) to receive the three sunscreens plus a control group with no sunscreen. The CIEL* a* b* formula was used to obtain the color measurements. Statistical Analysis Used: One way ANOVA test and Tukey's HSD test for multiple comparisons was used to analyse the data. Results: The ΔE values had changed for all samples throughout the aging process. Conclusion: Soltan showed promising results in protecting the dark-shaded samples in the outdoor environment only.


Assuntos
Protetores Solares , Tempo (Meteorologia) , Humanos , Protetores Solares/farmacologia , Cor , Elastômeros de Silicone , Raios Ultravioleta/efeitos adversos
17.
J Indian Prosthodont Soc ; 23(4): 384-390, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37861616

RESUMO

Aim: The aim was to evaluate and compare the cell viability, tear bond strength, and shore hardness of MDX4-4210 silicone reinforced with titanium dioxide and silver nanoparticles in 1%, 2%, and 3%. Settings and Design: The study design involves in vitro comparative study. Materials and Methods: MDX4-4210 silicone incorporated with 1%, 2%, and 3% by weight of silver and titanium dioxide nanoparticles. A total of 112 specimens were prepared and grouped into 7, with 16 specimens in each group. Group 1 - control, Groups 2, 3, and 4 were 1%, 2%, and 3% silver, respectively. Groups 5, 6, and 7 were 1%, 2%, and 3% titanium dioxide nanoparticles, respectively. Cell viability was tested by MTT ASSAY on MG63 cell lines, tear bond strength was tested by peeling force in universal testing machine, and Shore A hardness was tested in durometer. Statistical Analysis Used: The cell viability values were statistically analysed using one-way analysis of variance, and Tukey honestly significant difference test, tear bond strength and shore hardness values were analysed using Mann-Whitney test. Results: Based on the MTT ASSAY test, 1% silver nanoparticles incorporated MDX4-4210 silicone showed maximum cell viability of 42.10%, whereas minimum cell viability was 18.06% for 3% of titanium dioxide-reinforced silicone. The mean value of tear bond strength of 1% silver and 1% titanium dioxide nanoparticles reinforced room temperature vulcanized maxillofacial silicone were 62.81 ± 3.637 N/m and 59.69 ± 5.313 N/m and the mean value of shore hardness of room temperature vulcanized of 1% silver and 1% titanium dioxide nanoparticles reinforced room temperature vulcanized maxillofacial silicone were 38.06 ± 1.237 and 36.75 ± 1.291. Conclusion: Cell viability of 1% silver nanoparticles reinforced MDX4-4210 silicone was higher in comparison to the other groups, and tear bond strength and shore hardness were significantly higher in 1% silver nanoparticles reinforced silicone compared to 1% titanium nanoparticles reinforced MDX4-4210 silicone.


Assuntos
Nanopartículas Metálicas , Titânio , Titânio/farmacologia , Elastômeros de Silicone/química , Elastômeros de Silicone/farmacologia , Prata/farmacologia , Sobrevivência Celular , Resistência à Tração , Teste de Materiais
18.
Biomater Sci ; 11(22): 7311-7326, 2023 Nov 07.
Artigo em Inglês | MEDLINE | ID: mdl-37847519

RESUMO

Rosin is a characteristic natural renewable resource. In view of the unique hydrogenated phenanthrene ring skeleton structure of rosin, it can be designed and synthesized to modify silicone rubber for improving its mechanical properties, thermal stability, and other properties. In this paper, the research progress of silicone rubber modified by rosin and its derivatives is reviewed, including internal or surface modification of room temperature or high temperature vulcanized silicone rubber. The different chemical modifications and polymerization pathways to obtain bio-based silicone rubber (e.g. rosin-based silicone cross-linking agent, filler compound rosin-based silicone cross-linking agent, rosin-based polymer, and rosin quaternary ammonium salt bifunctional antibacterial coating) are discussed and its research prospect is reviewed. Overall, the present review article will provide a quantitative experimental basis for rosin to produce bio-renewable multifunctional silicone rubber to increase our level of understanding of the behavior of this important class of silicone rubber and other similar bio-based polymers.


Assuntos
Resinas Vegetais , Elastômeros de Silicone , Elastômeros de Silicone/química , Resinas Vegetais/química , Antibacterianos , Polímeros/química
19.
ACS Appl Mater Interfaces ; 15(40): 47810-47821, 2023 Oct 11.
Artigo em Inglês | MEDLINE | ID: mdl-37782773

RESUMO

Developing coating materials with low cytotoxicity and high antimicrobial activity has been recognized as an effective way to prevent medical device-associated infections. In this study, a maleic anhydride terpolymer (PPTM) is synthesized and covalently attached to silicone rubber (SR) surface. The formed coating can be further cross-linked (SPM) through the self-condensation of pendent siloxane groups of terpolymer. No crack or delamination of SPM was observed after 500 cycles of bending and 7 day immersion in deionized water. The sliding friction force of a catheter was reduced by 50% after coating with SPM. The SPM coating without adding any extra antibacterial reagents can kill 99.99% of Staphylococcus aureus and Escherichia coli and also significantly reduce bacterial coverage, while the coating displayed no antimicrobial activity when maleic anhydride groups of SPM were aminated or hydrolyzed. The results of the repeated disinfection tests showed that the SR coated with SPM could maintain 87.3% bactericidal activity within 5 cycles. Furthermore, the SPM coating only imparted slight toxic effect (>85% viability) on L929 cells after 36 h of coculture, which is superior to the coating of aminated SPM conjugated with the antimicrobial peptide E6. The terpolymer containing maleic anhydride units have great potential as a flexible and durable coating against implant infections.


Assuntos
Anti-Infecciosos , Anidridos Maleicos , Biofilmes , Anti-Infecciosos/farmacologia , Antibacterianos/farmacologia , Antibacterianos/química , Cateteres/microbiologia , Elastômeros de Silicone/química , Escherichia coli , Materiais Revestidos Biocompatíveis/farmacologia , Materiais Revestidos Biocompatíveis/química
20.
Sci Prog ; 106(4): 368504231205392, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37814535

RESUMO

The limited service life of craniofacial prostheses due to degradation and color instability is a significant challenge. This in vitro study aimed to determine how zirconium dioxide (ZrO2) nanoparticles affect the color stability of M511 heat temperature vulcanizing (HTV) maxillofacial silicone elastomers after artificial aging. ZrO2 nanoparticles were added at concentrations of 1, 2, and 3 wt% to M511 HTV silicone elastomer. Two intrinsic silicone pigments were used (red and mocha). Silicone with pigment and without ZrO2 nanoparticles were used as the control. Eighty disk-shaped specimens were fabricated and divided into eight experimental groups, each containing ten specimens (n = 10). All specimens were subjected to artificial aging, and color changes were recorded at 252, 504, and 1008 h intervals. The L*a *b * values were measured using a colorimeter and the CIE-Lab system. To interpret the recorded color differences, a 50:50 percent perceptibility threshold (ΔE* = 1.1) and acceptability threshold (ΔE* = 3.0) were implemented. A one-way analysis of variance and Tukey's post hoc test at a significance level of 0.05 were used for the statistical analysis. We found that every evaluated specimen group exhibited a chromatic change (ΔE* > 0). The ΔE* values for the mocha pigments with and without ZrO2 nanoparticles were below the perceptible threshold (1.1 units). The ΔE* values of the red pigment with and without ZrO2 nanoparticles were significantly higher than the acceptable threshold (P < 0.000). According to the findings of this in vitro study, all the specimens underwent color changes (ΔE* > 0). The red pigment exhibited highly significant chromatic alterations. In contrast, mocha pigments with and without ZrO2 nanoparticles exhibited the least color change and were below the perceptible threshold. ZrO2 nanoparticles provided important protection and showed a reduction in color change.


Assuntos
Temperatura Alta , Elastômeros de Silicone , Cor , Teste de Materiais , Pigmentação em Prótese
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...